PMP AUTOMATION PVT. LTD.
DELTA Make PLC
  Company Profile | Products| Enquiry Form | Contact Us | Home
dvp-eh

Standard Features :

1. 32 basic instructions, 212 application instructions (includes 16/32 bits instruction)
2. 15872 Steps program capacity
3. 512 I/O points
4. 4096 Internal auxiliary relays, 1024 steprelays, 256 timers, 256 counters, 10000 data registers, 1600 file registers and 16 index registers

dvp-eh5. Built-in RTC with perpetual calender
6. Built-in 2-point analog knob (use with VRRD and VRSC) and switch for RUN/STOP
7. 32 bits high-speed counter used for high performance model could reach 250 KHz
8. 2 high-speed pulse outputs for high performance model could reach 200 KHz
9. 8 expansion modules (without using I/O point) could connect to function expansion modules, such as AD, DA, XA, TC, PT and etc.
10. MPU expansion function card includes RS-232, RS-485/422, 8-point DIP switch, 6-point analog knob , program storage memory card and setting display.


dvp-eh

Standard Features :

1. 4096 Internal auxiliary relays, 1024 step relays, 5000 file registers, 1600 data registers, 8 index registers, 256 timers.
2. 32 basic instructions, 185 application instructions (includes 16/32 bits instruction)
3. 7920 Steps program capacity
4. 256 I/O points

dvp-ep5. Built-in RTC with perpetual calender
6. Built-in 2-point analog knob (use with VRRD and VRSC) and switch for RUN/STOP
7. 6-point external interrupt,2-point timer interrupt,6-point high-speed counter interrupt
8. 8 expansion modules (without using I/O point) could connect to function expansion modules, such as AD, DA, XA, TC, PT and etc.
9. RS-232C is Mini-DIN terminal (COM1)
10. MPU expansion function card includes RS-232, RS-485/422, 8-point DIP switch, 6-point analog knob and etc.
11. 32-bit single-phase high-speed counter : 10kHz (total of 40kHz). Input points X0, X1 could be higher speed counter & single phase could reach to 20kHz
12. 200 16-bit counters and 35 32-bit counters
13. 2-point high-speed output could reach 20Khz


dvp-eh

Standard Features :
Specifications

1. 32 Basic sequential (Including STL / RET) and 79 application commands (127 including the 32-bit commands)
2. EEPROM is utilized for program storage. The capacity of 4K models is 3792 STEPS.
3. Extension of the input and output point could both reach 128 points, respectively.

dvp-ep4. Internal auxiliary relay M)-M1279. 16-bit Timer (T0~T127) and counter (C0~C127) each possesses 128 of them and each of them could be utilized independently.
5. Data register D0~D599 and D1000~D1143 with 192 power retaining zones in the 4K model.
6. Pointers utilize P0~P63 to support the calling of subordinate programs and to execute 4 external interruptions (I001~I301).
7. There are 1332-bit high-speed counters (C235~C254). The one-phase high-speed counter with 5KHz. The two-phase (A and B) high-speed counter with (2KHz).
8. One PWM output on Y1.
9. Two plus output on Y0, Y1(PLSY). The single-axis PLSY has a 10kHz output and the double-axis is 5kHz output.
10. The EX model possesses the A/D (4-CH, 10bit) and D/A (2-CH,8bit) functions.

Built-in Interface of RS-232

  1. Could directly with handheld programming panel (HPP). (C0nnect with DVPACAB115)
  2. Could directly with PC. (Connect with DVPACAB215)
  3. Could directly with human machine interface (HMI). Connect with DVPACAB315

Built-in Interface of RS-485

  1. Could connect with PC (the PC terminal should be equipped with a RS-485, RS-232 converter).
  2. Could connect with the human-machine interface, HMI, Could also connect with equipment possesses the ASCII communication control mode.
  3. The PLC could serve as the MASTER/ SLAVE terminal that possesses the MODBUS interface and thus could drive up the specific convenient commands (which support the ASCII / RTU modes), MODRD and MODWR; moreover; it could connect directly with Delta’s VFD-M/ P/ B/ S/ L and V Series Inverter, Furthermore, there are specific commands, FWD/ REV/RDST/ RSTEF/ STOP, designed especially for Delta’s VFD-A Series Inverter.
  4. PLC will automatically handle any communication abnormalities, ASCII words and the conversion and checksum of the HEX numerical values.

Self-Examination and Protection

  1. Examine on the exceeding system execution time, illegitimate commands, error usage of the operands, and program grammar.
  2. Self-examination on the hard drive: CPU/ ROM/ RAM and the Peripherals
  3. Users could provide 4 ASCII words to serve as the MPU password, and the password could be used to prevent arbitrary read-out and destruction of the programs would be provided to remove the original MPU password (however, it will entirely delete all the programs within the MPU).

dvp-eh

Standard Features :
Specifications

1. Two high speeds outputs. One PWM output on Y1 and one plus output on Y0, Y1 (PLSY). The single-axis PLSY has a 10kHz output and the double-axis is 5KHz output.
2. To insure security, a 4-bit ASCII character password is offered on the main processing unit.

dvp-ep3. Built-in RS-232 and RS-485 communication ports.

    1. RS-232 port connects directly with an HPP, PC and HMI (human-machine interface).
    2. RS-485 connects directly with a PC or HMI (human-machine interface). It could also     connect with equipment using standard ASCII communication protocols

4. Micro modular design. The back plane is built as extensions are added (no rack needed).
5. MODBUS RTU/ASCII.
6. 4K step memory capacity